ABSTRAK Nama : Dewi Sulistyowati Program Studi : Kesehatan Lingkungan Judul : EfektifitasInstalasiPengolahan Air Limbah (IPAL) dalammemperbaikikualitas air limbah(COD, BOD, TSS, MinyakdanLemak, Amonia (NH3), dan Total Coli) di RumahSakitIbudanAnakRestiMulyaTahun 2017. Rumah Sakit Ibu dan Anak Resti Mulya dalam mengelola limbah cair menggunakan IPAL dengan sistem biofilter aerob-anaerob pada tahun 2014. Penelitian ini membahas efektifitas Instalasi Pengolahan Air Limbah di Rumah Sakit Ibu dan Anak Resti Mulya. Penelitian ini merupakan penelitian yang bersifat deskripsi observasional dengan pendekatan cross sectional. Hasil Penelitian terhadap kualitas effluent untuk parameter TSS, COD, BOD, minyak dan lemak tidak melebihi baku mutu yang ditetapkan oleh Pergub DKI Jakarta No. 69 tahun 2013 dan MenLH No. 05 tahun 2014. Sedangkan untuk parameter amonia dan total Coliform melebihi baku mutu yang ditetapkan. Rata-rata kualitas effluent untuk masing-masing parameter adalah : TSS 22,96 mg/L, amonia 8,90 mg/L, minyak dan lemak 0,995 mg/L, COD 50,61 mg/L, BOD 15,43 mg/L, dan total Coliform adalah sebesar 5.838 MPN/100 ml. Sedangkan berdasarkan analisis hasil laboratorium, efisiensi penurunan kadar pencemar untuk setiap parameter adalah : TSS 25,27%, amonia 56,26%, minyak dan lemak 50,37%, COD 54,36%, BOD 34,17%, dan total Coliform sebesar 60.81%. Persentase efisiensi IPAL dapat diketahui tidak hanya berdasarkan hasil outlet melainkan dengan menguji inlet secara berkala. Apabila parameter amonia, BOD, dan COD melebihi baku mutu yang telah ditetapkan , maka tindakan yang dapat dilakukan adalah dengan memperbaiki sistem aerasi dan melakukan treatment dengan menambahkan zat penetral seperti PAC.
Kata kunci : Efektifitas, IPAL, TSS, COD, BOD, Minyak dan Lemak, Amonia, Total Coliform

Mother and Child Resti Mulya Hospital in managing Waste Water Treatment Plant (WWTP) with aerob-anaerob biofilter system in 2014. This research discuss effectiveness of Waste Water Treatment Plant Installation at Resti Mulya Hospital. This research is an observational description with cross sectional approach. The result of the research on the effluent quality for TSS, COD, BOD, Oil and fat parameters do not exceed the quality standard specified by Jakarta governor regulation No. 69/2013 and regulation of environment minister number 05/2014. As for amonia and total Coliform parameters exceeded standard Quality set. The average quality of effluent for each parameter are TSS 22,96 mg/L, amonia 8,90 mg/L, oil and fat 0,995 mg/L, COD 50,61 mg/L, BOD 15,43 mg/L, and the total Coliform is 5,838 MPN/100 ml. While based on laboratory analysis, efficiency of decreasing pollutant level for each parameter are : TSS 25,27%, ammonia 56,26%, oil and fat 50,37%, COD 54,36%, BOD 34,17% and total colimorm amounted to 60,81%.The percentage of WWTP efficiency can be known not only based on outlet results but by regularly testing the inlet. If the ammonia, BOD, and COD parameters exceed the predefined quality standard, then the action that can be done is to improve the aeration system and perform treatment by adding a neutralizing agent such as PAC.
Keyword : Effectiveness, WWTP, TSS, COD, BOD, Oil and Fat, Amonia, Total Coliform

Metadata

Jenis Koleksi : S1 - Skripsi
No. Panggil : S-9515
Pengarang :
Nama badan : Universitas Indonesia. Fakultas Kesehatan Masyarakat. Kesehatan Lingkungan
Program Studi/Peminatan : Kesehatan Lingkungan
Promotor/Pembimbing :
Ko-Promotor/Penguji :
Subjek :
Penerbitan : Depok : FKM UI, 2017
Kode Bahasa : ind
Tipe Carrier :
Deskripsi Fisik : hlm, llh 30 cm
Departemen-Jurusan : Kesehatan Lingkungan
Kata Kunci : effectiveness; WWTP; TSS; COD; BOD; Oil and fat ; amonia; total coliform; efektifitas; IPAL; TSS; COD; BOD; minyak dan lemak; amonia; total coliform
Lembaga Pemilik : Pusinfokesmas FKM UI

File Digital: 2 

Shelf
 DEWI SULISTYOWATI -skripsi-fuletk-2017 sec.pdf ::
 RINGKASAN - DEWI SULISTYOWATI - 1406647644 .docx ::
 
Catatan: Hanya file pdf yang dapat dibaca online
Menu Anggota Pusat Informasi Kesehatan Masyarakat
No. Panggil No. Barkod Ketersediaan Lokasi
S-9515 S-9515 TERSEDIA Lantai 5 / Annex
Ulasan:
Tidak ada ulasan pada koleksi ini: 127905

Sampul

cover

Lihat juga:

:: Pengguna : Pusat Informasi Kesehatan Masyarakat
Library Automation and Digital Archive