S2 - Tesis

Faktor Risiko Lama Pemakaian Ventilator Mekanik dengan Kejadian Ventilator Associated Pneumonia (VAP) di Ruang ICU RSUD Tarakan jakarta Tahun 2014 - 2017

Ema Suryani; Pembimbing: Zakianis; Ririn Arminsih; Penguji: Ema Hermawati, Satria Pratama, Fachrudin Ali Achmad (FKM UI, 2019)

Abstrak

Ventilator mekanik merupakan salah satu aspek yang penting dan banyak digunakan bagi perawatan pasien kritis di Intensif Care Unit (ICU). Lama pemakaian ventilator mekanik merupakan salah satu faktor penting penyebab VAP. Penelitian ini bertujuan untuk mengetahui hubungan antara lama pemakaian ventilator mekanik dengan kejadian Ventilator Associated Pneumonia (VAP) di ICU RSUD Tarakan Jakarta tahun 2014 2017 Jenis peneltian analitik, desain penelitian studi potong lintang (cross sectional). Metode pengambilan sampel adalah consecutive sampling dengan cara observasi catatan medik pasien yang memakai ventilator mekanik minimal 48 jam dan dirawat minimal 3 hari di ruang ICU RSUD Tarakan Jakarta Tahun 2014 2017 dan sampel berjumlah 106 sampel. Data dianalisis dengan uji chi square, t-test independent, dan regresi logistik. Prevalensi Kejadian Ventilator Associated Pneumonia (VAP) sebesar 17,9%. Lama pemakaian ventilator mekanik dan lama perawatan secara statistik menunjukkan berhubungan yang bermakna dengan kejadian VAP. Sedangkan variabel umur, penyakit yang mendasari, posisi tidur, pembedahan dan pemberian antibiotik secara statistik tidak menunjukkan hubungan yang bermakna terhadap kejadian Ventilator Associated Pneumonia (VAP). Hasil analisis multivariat diperoleh bahwa variabel lama pemakaian ventilator mekanik merupakan variabel yang paling dominan berhubungan dengan kejadian VAP, dengan OR=5,265 (95% CI: 1,084-25,548)
Mechanical ventilator is one of the important aspects and frequently used for treatment of critical patients in the Intensive Care Unit (ICU). The duration for using mechanical ventilator is important factors caused VAP. This research aimed to find the correlation between duration of mechanical ventilator use and Ventilator Associated Pneumonia (VAP) case in ICU RSUD Tarakan Hospital Jakarta 2014 2017. This was an analitic research with observational study (cross-sectional design). Sampling method used consecutive sampling by observed medical records of patients who used mechanical ventilator at least 48 hours and treated at least 3 days in ICU RSUD Tarakan Hospital Jakarta January 2014 December 2017, as many as 106 sampels. Data was analyzed by chi-square, t-test independent, and logistic regression. Prevalention of Ventilator Associated Pneumonia (VAP) was about 17,9%. Duration of mechanical ventilator use and duration of treatment had significant correlation to VAP. While age, basic disease, sleep position, surgery and antibiotic treatment insignificant to VAP. Multivariate analysis showed that duration of mechanical ventilators use variable was the most dominant variable related to VAP OR=5,265 (95% CI: 1,084-25,548)

Metadata

Jenis Koleksi : S2 - Tesis
No. Panggil : T-5509
Pengarang :
Nama badan : Universitas Indonesia. Fakultas Kesehatan Masyarakat. Administrasi dan Kebijakan Kesehatan
Program Studi/Peminatan : Kesehatan Masyarakat
Promotor/Pembimbing :
Ko-Promotor/Penguji :
Subjek :
Penerbitan : Depok : FKM UI, 2019
Kode Bahasa : ind
Tipe Carrier :
Deskripsi Fisik : xviii, 91 hlm. Il; 30 cm
Departemen-Jurusan : Kesehatan Masyarakat
Kata Kunci : Faktor Risiko, Ventilator, Ruang ICU, RSUD
Lembaga Pemilik : Pusinfokesmas FKM UI

File Digital: 2 

Shelf
 Ema Suryani-Tesis-FUlltext-FKM-2018.pdf ::
 Ema Suryani-Naskash Ringkas-FKM-2018.docx ::
 
Catatan: Hanya file pdf yang dapat dibaca online
Menu Anggota Pusat Informasi Kesehatan Masyarakat
No. Panggil No. Barkod Ketersediaan Lokasi
T-5509 T-5509 TERSEDIA Lantai 5 / Annex
Ulasan:
Tidak ada ulasan pada koleksi ini: 131397

Sampul

cover

Lihat juga:

:: Pengguna : Pusat Informasi Kesehatan Masyarakat
Library Automation and Digital Archive