S1 - Skripsi

Analisis Kesesuaian Sistem Proteksi Kebakaran Aktif PT X Tahun 2012

Affan Nurrohman Wiguna; Pembimbing: Kurniawidjaja, Meily / Penguji: Tejsmaya, Mila; Rakhmadi, Triyono (FKM-UI, 2013)

Abstrak

Sistem Proteksi Kebakaran Aktif merupakan suatu bentuk penanggulangankebakaran menggunakan sarana manual atau otomatis yang bertujuan untukmencegah atau meminimalkan kerugian akibat kebakaran. Penelitian kualitatif mengenai sistem proteksi kebakaran aktif dilakukan di PT X dengan pendekatan deskriptif analitik. Gambaran sistem proteksi kebakaran aktif dilihat darikesesuaian pelaksanaan dengan Permen PU No. 2006 PRT/M/2008, SNI 03-1745-2000, SNI 03-3985-2000, SNI 03-3989-2000, SNI 03 6570-2001, dan NFPA 15 melalui observasi lapangan, wawancara, dan telaah dokumen. Hasil penelitian menunjukkan bahwa penerapan Alarm Kebakaran, Detektor Kebakaran, Hidran,dan Water Spray Fixed System telah sesuai, namun masih terdapat beberapa ketidak sesuaian pada Titik Panggil Manual, Springkler, Alat Pemadam Api Ringan(APAR), dan Pompa Pemadam Kebakaran yang diakibatkan oleh kurangnyapersonil safety dan pemeliharaan sara proteksi kebakaran yang belum optimal. Olehkarena itu, diperlukan upaya perbaikan dengan menambah jumlah personil safetydan perbaikan pada kualitas pemeliharaan sarana proteksi kebakaran aktif.Kata kunci :Analisis, Sistem Proteksi Kebakaran
Active Fire Protection System is one of fire prevention using manual or automatedfacilities intended to prevent or minimize losses due to fire. Qualitative research onactive fire protection systems conducted at PT X was performed by descriptiveanalytic approach. Overview of active fire protection systems seen fromcompliance of implementation with Permen PU No. 26/PRT/M/2008, SNI 03-1745-2000, SNI 03-3985-2000, SNI 03-3989-2000, SNI 03 6570-2001, and NFPA15 through field observations, interviews, and document review. The resultsshowed that the implementation of Fire Alarm, Fire Detector, Hydrant, and WaterSpray Fixed System are compliant, but there are still some discrepancy in theManual Call Point, Sprinkler, Portable Fire Extinguisher, and Fire Pump caused bya lack of safety personnel and maintenance of fire protection facilities was notoptimal. Therefore, improvement efforts needed by adding the number of safetypersonnel and improvement in the maintenance quality of active fire protection.Keywords :Analysis, Fire Protection System

Metadata

Jenis Koleksi : S1 - Skripsi
No. Panggil : S-7649
Pengarang :
Subjek :
Penerbitan : Depok : FKM-UI, 2013
Kode Bahasa : ind
Tipe Carrier :
Deskripsi Fisik : xv, 106 hlm. : il; 30 cm.
Departemen-Jurusan :
Kata Kunci : Analisis; Sistem proteksi kebakaran
Lembaga Pemilik : Pusinfokesmas FKM UI

File Digital: 1 

Shelf
 Affan Nurroham Wiguna-Skripsi-Fulltext-FKM-2013.pdf ::
 
Catatan: Hanya file pdf yang dapat dibaca online
Menu Anggota Pusat Informasi Kesehatan Masyarakat
No. Panggil No. Barkod Ketersediaan Lokasi
S-7649 S-7649 TERSEDIA Lantai 5
Ulasan:
Tidak ada ulasan pada koleksi ini: 90212

Sampul

cover

Lihat juga:

:: Pengguna : Pusat Informasi Kesehatan Masyarakat
Library Automation and Digital Archive