Ditemukan 26453 dokumen yang sesuai dengan query :: Simpan CSV
Kata kunci : Keselamatan kebakaran, gedung, perkantoran, CFSES.
Kata kunci: keselamatan kebakaran, gedung, CFSES, NFPA
This study used a semi-quantitative approach with a descriptive research design in accordance with NFPA 101A: Guide on Alternative Approaches to Life Safety This studi aims to evaluate the implementation of the fire safety on buildings fire safety by using Computerized Fire Safety Evaluation System (CFSES) software at X Hotel located in Jakarta. The evaluation is done based on the suitability of 12 safety parameters and additional requirements that exist in NFPA 101A: Guide on Alternative Approaches to Life Safety. Sample which was evaluated is the whole building of X Hotel. The implementation of fire safety in the whole building is under the minimum safety requirements of NFPA 101: Life Safety Code.
Keyword: fire safety, building, CFSES, NFPA
Kata kunci: CFSES, keselamatan kebakaran, gedung, Museum Nasional.
Kata kunci : CFSES, keselamatan kebakaran, gedung, safety parameters, NFPA
This study discusses the evaluation of fire safety of buildings using softwareComputerized Fire Safety Evaluation System (CFSES) at the Ministry of Tourismand Creative Economy, which is located in Central Jakarta. The evaluation isbased on suitability 12 safety parametes and additional requirements in NFPA101A: Alternate Approaches to Life Safety to NFPA 101: Life Safety Code. Theresults showed that the application of fire safety at the Ministry of Tourism andCreative Economy not meet the minimum safety requirements in NFPA 101: LifeSafety Code.
Keyword : CFSES, fire safety, building, safety parameters, NFPA
Kata kunci: Keselamatan kebakaran, CFSES, safety parameter, gedung, NFPA
This thesis uses descriptive study design with semi-quantitative approach and has purpose to evaluate the implementation of fire safety of buildings by using Computerized The Safety Evaluation System (CFSES) software at Hospital X Depok. The evaluation is based on 12 safety parameters and additional requirements in NFPA 101: Life Safety Code. The assessment of this study is North Building, South Building and Operating Room Hospital X Depok . Based on the result of the study, the conclusion is that building in Hospitas X Depok in general has not qualified yet with the minimum safety requirements in NFPA 101: Life Safety Code.
Keywords: Fire safety, CFSES, safety parameters, building, NFPA
Kata kunci: CFSES, keselamatan kebakaran, gedung, NFPA.
Cases of fires in educational buildings are tend to be high. Educationalbuilding is a place where academic communities do the activities and store manyarchives, high-value documents and useful for knowledge. This research aims toevaluate the implementation of the fire safety on the building of the Faculty ofLaw, University of Indonesia located in Depok, West Java. This study used asemi-quantitative approach with a descriptive research design in accordance withNFPA 101A: Guide on Alternative Approaches to Life Safety and assisted withthe use of software Computerized Fire Safety Evaluation System (CFSES). Theevaluation is done based on the suitability of 12 safety parameters and additionalrequirements that exist in NFPA 101A: Alternate Approaches to Life Safety.Samples were evaluated consists of three buildings, namely building A, buildingB, and C. Based on the results of the research, the application of fire safety in thewhole buildings are under the minimum safety requirements of NFPA 101: LifeSafety Code.
Keyword: CFSES, fire safety, building, NFPA
ABSTRAK Kebakaran gedung bertingkat bisa memakan korban jiwa yang banyak jika tidak diantisipasi sejak dini dengan memfasilitasi gedung tersebut dengan fasilitas keselamatan dan pelatihan kebakaran. Evaluasi keselamatan kebakaran adalah salah satu cara untuk mengetahui kesiapan sebuah gedung dalam menghadapi kejadian kebakaran. Tesis ini membahas evaluasi keselamatan kebakaran digedung Menara Karya dengan bantuan perangkat lunak Computerised Fire Safety Evaluation System (CFSES). Perangkat Lunak CFSES membantu memberikan perhitungan hasil observasi peneliti terhadap 12 parameter safety berdasarkan NFPA 101A Alternate Approaches to Life Safety yaitu Fire Safety Evaluation System. Dari hasil evaluasi terhadap 12 parameter akan didapatkan nilai kontrol penyebaran api (fire control), nilai jalur keselamatan keluar gedung (egress) dan nilai keselamatan umum (general safety) di gedung tersebut. Kemudian nilai hasil penelitian dibandingkan dengan nilai yang telah ditetapkan oleh NFPA 101 A untuk klasifikasi gedung tersebut. Jika nilai yang didapat dari hasil evaluasi berada dibawah nilai persyaratan maka perlu tindak lanjut untuk memperbaiki parameter safety yang melekat pada gedung tersebut untuk meningkatkan kesiapan gedung dalam menghadapi kebakaran. Hasil penelitian ini memberikan saran kepada pihak gedung untuk memperbaiki parameter vertical opening pada shaft kabel yang ada pada gedung tersebut untuk dilengkapi segera denga fire stop sehingga perambatan api kelantai atas dan penyebaran asap bisa dihambat.
ABSTRACT In case of fire in high rise building able to make a lot of victims if it is not anticipated early through provide firefighting equipment on that building and enhance knowledge of occupancies related to fire drill training.Fire safety evaluation is a way to get information how the building ready to face in case of fire. This thesis discusses the evaluation of fire safety in the Menara Karya building using software Computerised Fire Safety Evaluation System (CFSES). The software CFSES help to provide the calculation of the 12 observations researcher safety parameters based on NFPA 101A Alternate Approaches to Life Safety is Fire Safety Evaluation System. From the results of an evaluation of 12 parameters which fire control, egress and general safety in the building. Then the value of the results of the study compared with the value set by the NFPA 101 A for the classification of its building. If the value obtained from the results of the evaluation are below from mandatory requirement it is necessary to improve safety parameters attached to the building to improve the building's readiness in the face of fire. The results provide advice to the building to improve the parameters of vertical shaft opening on the existing wiring in the building to include premises immediately stop making fire onto the floor above the fire propagation and spread of smoke could be inhibited.
Kata kunci: Keselamatan kebakaran, CFSES, safety parameter, gedung, NFPA
This thesis uses descriptive study design with semi-quantitative approach and has purpose to evaluate the implementation of fire safety of buildings by using Computerized The Safety Evaluation System (CFSES) software at Faculty of Dentistry University of Indonesia located in Salemba Raya, Central Jakarta. The evaluation is based on 12 safety parameters and additional requirements in NFPA 101: Life Safety Code. The assessment of this study is building A and C Faculty of dentistry University of Indonesia. Based on the result of the study, the conclusion is that building in Faculty of Dentistry University of Indonesia has not qualified yet with the minimum safety requirements in NFPA 101: Life Safety Code.
Keywords: Fire safety, CFSES, safety parameters, building, NFPA
Hasil evaluasi Gedung Utama menunjukkan bahwa kontrol penyebaran api mendapatkan nilai -9 dari standar persyaratan minimum -4. Sistem jalan keluar mendapatkan nilai -12.5 dari standar 0. Sedangkan keselamatan kebakaran umum mendapatkan nilai -17 dari standar -4. Hasil evaluasi Gedung Departemen Kimia menunjukkan bahwa kontrol penyebaran api mendapatkan nilai -9,5 dari standar persyaratan minimum -4. Sistem jalan keluar mendapatkan nilai -5.5 dari standar 0. Sedangkan keselamatan kebakaran umum mendapatkan nilai -8 dari standar -4.
Hasil penelitian menyimpulkan bahwa penerapan keselamatan kebakaran di Gedung Fakultas kedokteran Universitas Indonesia belum memenuhi persyaratan keselamatan minimum pada NFPA 101: Life Safety Code.
Kata kunci : keselamatan kebakaran, gedung, CFSES, Fakultas Kedokteran Universitas Indonesia
This study discusses evaluation of the fire safety implementation of buildings using software Computerized Fire Safety Evaluation System (CFSES) at Faculty of Medicine, University of Indonesia, located in Salemba, Central Jakarta. The evaluation was done based on the suitability of 12 safety parameters and additional requirements in NFPA 101A: Alternate Approaches to Life Safety with standards NFPA 101: Life Safety Code. Design of this study is descriptive with a semi-quantitative approach. Samples are the Main Building and the Department of Chemistry Building, Faculty of Medicine.
Results of main building evaluation shows that the score of fire control is -9, score of egress is -12.5, and score of general fire safety is -17. Meanwhile, for chemistry building, the score for fire control is -9.5, score of egress is -5.5, and score of general fire safety is -8.
The study concluded that the fire safety implementation in the Faculty of Medicine University of Indonesia has not met the minimum safety requirements in NFPA 101: Life Safety Code.
Keywords: fire safety, building, CFSES, Faculty of Medicine University of Indonesia