Ditemukan 4 dokumen yang sesuai dengan query :: Simpan CSV
Prapti Setyaningsih; Pembimbing: Indri Hapsari Susilowati; Penguji: Chandra Satrya, Suprapto, Abdillah
Abstrak:
Penelitian dengan judul Fire Load kamar asrama Y di Jakarta merupakan penelitian deskriptif komparatif. Penelitian ini menggambarkan nilai fire load yang berasal dari bahan perlengkapan di dalam ruangan (kamar) baik yang bersifat fixed seperti kusen dan pintu maupun yang bersifat movable seperti kursi, tempat tidur dan lainnya. Perlengkapan kamar kemudian dikategorikan menurut tipe pertumbuhan api, yaitu ultrafast, fast, medium dan slow. Waktu perkiraan evakuasi dihitung dengan menggunakan model matematis sederhana berdasarkan gambaran komponen sarana evakuasi gedung. Dari hasil penelitian terhadap 13 kamar asrama di asrama Y diketahui rata-rata nilai Fire Load adalah 356.0 MJ/m2 . Hasil tersebut melebihi survey yang dilakukan oleh puslitkim PU pada tahun 1997. Menurut tipe pertumbuhan apinya 66.6 % perlengkapan asrama memiliki sifat pertumbuhan api medium, 26.9 % perlengkapan memiliki pertumbuhan api sifat fast namun 6.5% perlengkapan asrama memiliki sifat pertumbuhan api ultra fast (waktu tumbuh 75 detik). Hasil perhitungan waktu evakuasi tanpa hambatan adalah 15 menit 48 detik pada siang hari dan 13 menit 31 detik pada malam hari. Keyword : Fire Load, Kamar, Waktu Evakuasi
Read More
T-4449
Depok : FKM-UI, 2015
S2 - Tesis Pusat Informasi Kesehatan Masyarakat
☉
Dwi Septiana; Pembimbing: Fatma Lestari; Penguji: Laksita Ri Hastiti, Stevan Deby Anbiya Muhamad Sunarno, Alfajri Ismail, Widiyo Weni Wigati
Abstrak:
Read More
Tesis ini membahas strategi evakuasi kebakaran dengan pendekatan pemodelan tiga dimensi (3D) di tiga rumah sakit milik PT X yang berlokasi di Balikpapan, Tarakan, dan Makassar. Saat ini, proses evakuasi dalam kondisi darurat dapat dianalisis melalui pemanfaatan perangkat lunak simulasi berbasis komputer yang mampu memodelkan dinamika pergerakan individu secara mendekati kondisi nyata. Pendekatan ini menjadi salah satu metode rekayasa yang efisien dalam menilai sejauh mana bangunan mampu mendukung proses evakuasi kebakaran. Agar simulasi ini menghasilkan gambaran yang akurat, diperlukan pula pemahaman yang komprehensif mengenai elemen-elemen pendukung evakuasi, terutama pada fasilitas pelayanan kesehatan yang memiliki penghuni dengan keterbatasan mobilitas dan tingkat kerentanan yang tinggi. Rumah sakit sebagai fasilitas layanan kesehatan memiliki tingkat risiko tinggi apabila terjadi kebakaran, terutama karena kompleksitas bangunan dan keterbatasan mobilitas pasien. Dalam penelitian ini dilakukan simulasi evakuasi 3D menggunakan perangkat lunak Pathfinder untuk menganalisis pergerakan penghuni dalam situasi darurat. Simulasi dilakukan berdasarkan data teknis bangunan dan karakteristik pengguna, termasuk skenario evakuasi pasien non-ambulatory menggunakan tempat tidur. Hasil pemodelan menunjukkan bahwa terdapat area kritis seperti ruang ICU dan rawat inap yang memiliki waktu evakuasi (Required Safe Egress Time) melebihi batas waktu aman (Available Safe Egress Time), yang mengindikasikan potensi kegagalan evakuasi jika tidak dilakukan perbaikan strategi. Selain itu, penelitian ini juga menilai tingkat kesesuaian sarana evakuasi terhadap standar dan regulasi teknis. Hasil penilaian menunjukkan bahwa ketiga rumah sakit memiliki tingkat kesesuaian rata-rata sebesar 81,3% dan masuk dalam kategori “Baik”. Namun, masih ditemukan kekurangan pada aspek penting seperti ketiadaan ramp dan fire lift untuk evakuasi pasien dalam kondisi tidak dapat berjalan. Penelitian ini menunjukkan perlunya perencanaan evakuasi yang lebih adaptif melalui strategi kesiapan personel tenaga medis, progressive horizontal evacuation dan peningkatan infrastruktur pendukung.
This thesis discusses fire evacuation strategies using a three-dimensional (3D) modeling approach at three hospitals owned by PT X, located in Balikpapan, Tarakan, and Makassar. Currently, emergency evacuation processes can be analyzed using computer-based simulation software that realistically models individual movement dynamics during emergencies. This approach serves as an effective engineering method to assess the extent to which a building supports evacuation during a fire event. To ensure simulation accuracy, a comprehensive understanding of evacuation support facilities is essential, particularly in healthcare settings where occupants often have limited mobility and higher vulnerability. Hospitals, as healthcare facilities, present a high level of fire risk due to their structural complexity and the mobility limitations of patients. This study utilized 3D evacuation modeling through Pathfinder software to simulate occupant movement in emergency scenarios. The simulation was based on building specifications and occupant characteristics, including scenarios involving the evacuation of non-ambulatory patients using beds. The results indicate that critical areas such as intensive care units (ICUs) and inpatient wards recorded Required Safe Egress Time (RSET) that exceeded the Available Safe Egress Time (ASET), suggesting a potential failure in evacuation without strategic improvements. In addition, the study evaluated the compliance level of evacuation facilities with technical standards and regulations. The findings showed that the three hospitals achieved an average compliance score of 81.3%, categorized as “Good.” However, deficiencies were found in essential aspects such as the absence of ramps and fire lifts for evacuating non-ambulatory patients. This study highlights the need for more adaptive evacuation planning through improved preparedness of medical personnel, the application of progressive horizontal evacuation, and the enhancement of supporting infrastructure.
This thesis discusses fire evacuation strategies using a three-dimensional (3D) modeling approach at three hospitals owned by PT X, located in Balikpapan, Tarakan, and Makassar. Currently, emergency evacuation processes can be analyzed using computer-based simulation software that realistically models individual movement dynamics during emergencies. This approach serves as an effective engineering method to assess the extent to which a building supports evacuation during a fire event. To ensure simulation accuracy, a comprehensive understanding of evacuation support facilities is essential, particularly in healthcare settings where occupants often have limited mobility and higher vulnerability. Hospitals, as healthcare facilities, present a high level of fire risk due to their structural complexity and the mobility limitations of patients. This study utilized 3D evacuation modeling through Pathfinder software to simulate occupant movement in emergency scenarios. The simulation was based on building specifications and occupant characteristics, including scenarios involving the evacuation of non-ambulatory patients using beds. The results indicate that critical areas such as intensive care units (ICUs) and inpatient wards recorded Required Safe Egress Time (RSET) that exceeded the Available Safe Egress Time (ASET), suggesting a potential failure in evacuation without strategic improvements. In addition, the study evaluated the compliance level of evacuation facilities with technical standards and regulations. The findings showed that the three hospitals achieved an average compliance score of 81.3%, categorized as “Good.” However, deficiencies were found in essential aspects such as the absence of ramps and fire lifts for evacuating non-ambulatory patients. This study highlights the need for more adaptive evacuation planning through improved preparedness of medical personnel, the application of progressive horizontal evacuation, and the enhancement of supporting infrastructure.
T-7415
Depok : FKM-UI, 2025
S2 - Tesis Pusat Informasi Kesehatan Masyarakat
☉
Putu Kriswidianto Saputra; Pembimbing: Zulkifli Djunaidi; Penguji: Fatma Lestari, Pertama, I Made Pasek Dwi
Abstrak:
SKRIPSI INI MEMBAHAS TENTANG GAP ANALISIS SISTEM PROTEKSI KEBAKARAN YANG ADA DI GEDUNG PUSAT ADMINISTRASI UNIVERSITAS INDONESIA PADA TAHUN 2017. PENELITIAN INI MERUPAKAN PENELITAN DESKRIPTIF ANALITIK DENGAN VARIABLE YANG DITELITI ADALAH SISTEM PROTEKSI KEBAKARAN PASIF (KONSTRUKSI BANGUNAN, KOMPARTEMEN, SARANA JALAN KELUAR, TANGGA DARURAT, PINTU DARURAT, DAN PETUNJUK JALAN KELUAR) DAN SISTEM PROTEKSI KEBAKARAN AKTIF (SPRINKLER, ALARM, DETEKTOR, APAR, DAN HIDRAN). HASIL PENELITIAN MENUNJUKAN RATA-RATA 83% KONDISI AKTUAL SESUAI DENGAN PERATURAN DAN MASIH ADA 17% GAP DENGAN PERATURAN. STANDAR YANG DIGUAKAN ADALAH PERATURAN MENTERI PEKERJAAN UMUM NO.26/PRT/M/2008, KEPUTUSAN MENTERI NEGARA PEKERJAAN UMUM NOMOR 10/KPTS/2000, PERATURAN MENTERI TENAGA KERJA DAN TRANSMIGRASI NO.4 TAHUN 1980, NFPA 13, DAN NFPA 72. DAN JUGA DILAKUKAN PERHITUNGAN WAKTU EVAKUASI DISETIAP LANTAI GEDUNG. KATA KUNCI: KEBAKARAN,GAP ANALISIS, SISTEM PROTEKSI KEBAKARAN AKTIF, SISTEM PROTEKSI KEBAKARAN PASIF, WAKTU EVAKUASI THIS STUDY DISCUSSED ABOUT GAP ANALYSIS OF FIRE PROTECTION SYSTEM IN ADMINISTRATION CENTER BUILDING OF UNIVERSITY OF INDONESIA IN 2017. THIS RESEARCH IS ANALYTIC DESCRIPTIVE RESEARCH. THE VARIABLES STUDIES WERE PASSIVE FIRE PROTECTION SYSTEM (BUILDING CONSTRUCTION, COMPARTMENT, MEANS OF EGRESS, EMERGENCY STAIRS, EMERGENCY DOORS, AND EXIT SIGN) AND ACTIVE FIRE PROTECTION SYSTEM (SPRINKLERS, FIRE ALARMS, DETECTORS, FIRE EXTINGUISHER, AND HYDRANTS). RESULTS SHOWED THAT AN AVERAGE OF 83% IS IN ACCORDANCE WITH THE REGULATION AND THERE WERE STILL 17% GAP WITH REGULATION. THE STANDARD USED IS PERATURAN MENTERI PEKERJAAN UMUM NO.26/PRT/M/2008, KEPUTUSAN MENTERI NEGARA PEKERJAAN UMUM NOMOR 10/KPTS/2000, PERATURAN MENTERI TENAGA KERJA DAN TRANSMIGRASI NO.4 TAHUN 1980, NFPA 13, AND NFPA 72. AND ALSO CALCULATED OF EVACUATION TIME IN EVERY FLOOR OF BUILDING. KEYWORD: FIRE, GAP ANALYSIS, ACTIVE FIRE PROTECTION SYSTEM, PASSIVE FIRE PROTECTION SYSTEM, EVACUATION TIME
Read More
S-9497
Depok : FKM UI, 2017
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Muhamad Reynaldi Pratama Jozarizal; Pembimbing: Fatma Lestari; Penguji: Laksita Ri Hastiti, Imam Santoso
Abstrak:
Read More
Skripsi ini membahas terkait strategi evakuasi dengan pemodelan 3D di Asrama UI. Simulasi evakuasi saat ini dapat dilakukan menggunakan pemodelan komputerisasi. Pemodelan komputer merupakan pendekatan rekayasa yang praktis untuk mengevaluasi kelayakan bangunan dalam melakukan proses evakuasi saat terjadi peristiwa kebakaran. Pemodelan ini juga harus didukung dengan ilmu pengetahuan yang mendasar terkait sarana evakuasi yang menunjang jalannya proses evakuasi. Gedung hunian bertingkat merupakan bangunan yang digunakan sebagai tempat tinggal bagi beberapa orang. Tidak menutup kemungkinan peristiwa kebakaran dapat terjadi di gedung hunian bertingkat yang menjadi tempat tinggal dan beraktivitas sehari-hari. Pada penelitian ini dilakukan modeling simulasi evakuasi secara 3D dengan menggunakan perangkat lunak pathfinders. Pathfinders digunakan untuk mengetahui pergerakan penghuni dalam kondisi darurat saat berada di gedung hunian bertingkat. Dalam penggunaan pathfinders ini dibutuhkan data terkait penghuni dan data terkait bangunan gedung. Hasil pemodelan evakuasi di Gedung Asrama UI ini menghasilkan waktu selama 2 menit 35,78 detik. Selain melakukan simulasi evakuasi, penelitian ini juga meneliti terkait tingkat kesesuaian implementasi sarana evakuasi. Hasil tingkat kesesuaian implementasi sarana evakuasi di Gedung Asrama UI menunjukan angka 56,67% dan dikategorikan ‘Kurang (K)’ karena masih ditemukan kondisi sarana evakuasi yang belum memenuhi standar dan peraturan yang berlaku.
This study discusses evacuation strategies using 3D modeling in Asrama UI. Evacuation simulations can now be conducted through computerized modeling. Computer modeling is a practical engineering approach for assessing the feasibility of buildings in carrying out evacuation processes during fire incidents. This modeling must also be supported by fundamental knowledge regarding evacuation facilities that facilitate the evacuation process. High-rise residential buildings are structures used as living spaces for multiple people. It is possible for fire incidents to occur in high-rise residential buildings, which serve as places for daily living and activities. In this study, a 3D evacuation simulation modeling was conducted using Pathfinder software. Pathfinder is used to analyze the movement of occupants in emergency conditions within high-rise residential buildings. The use of Pathfinder requires data related to building occupants and the building structure itself. The results of the evacuation modeling in the high-rise residential building showed a total evacuation time of 2 minutes and 35.78 seconds. In addition to conducting evacuation simulations, this research also examined the level of compliance in implementing evacuation facilities. The results indicated that the compliance level of evacuation facilities in the high-rise residential building was 56.67%, which is categorized as "Poor (K)" because several evacuation facilities were found to be non- compliant with applicable standards and regulations.
S-11833
Depok : FKM UI, 2025
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉