Ditemukan 39039 dokumen yang sesuai dengan query :: Simpan CSV
Warid Nurdiansyah; Pembimbing: Fatma Lestari; Penguji: Yulianto S Nugroho, Zukifli Djunaidi
S-4954
Depok : FKM-UI, 2007
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Antoni Bona Foncus Naibaho; Pembimbing: Syahrul Meizar Nashri; Penguji: Hendra, Yuni Kusminanti
S-6429
Depok : FKM-UI, 2011
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Dina Ramadhani; Pembimbing: Chandra Satrya; Penguji: Mila Tejamaya, Yuni usminanti
Abstrak:
Tangki timbun yang menyimpan premium memiliki risiko kebakaran dan ledakankarena premium bersifat flammable, reactive, dan mudah menguap. Oleh karenaitu, diperlukan penilaian risiko kebakaran dan ledakan pada tangki agar dapat dilakukan tindakan pencegahan dan meminimalisasi dampak yang mungkin terjadi. Penilaian risiko kebakaran pada tangki timbun dilakukan dengan menggunakan metode Dow;s Fire and Explosion Index. Objek penelitian adalah tangki timbun nomor 12 yang menyimpan premium dengan kapasitas 5.020 kL.Hasil penelitian menunjukkan bahwa nilai F&EI pada tangki timbun nomor 12sebesar 122,24. Hal ini berarti tangki timbun memiliki risiko kebakaran dan ledakan dengan kategori intermediate. Radius pajanan jika terjadi kebakaran da nledakan adalah 43,747 meter. Luas area terpajan jika terjadi kebakaran dan ledakan adalah 3.074,25 m2. Nilai pergantian properti dan seluruh peralatan yang rusak jika terjadi kebakaran dan ledakan adalah Rp 8.357.392.777,-. Denganfaktor kerusakan sebesar 0,50, maka jika terjadi kebakaran dan ledakan nilai kerugian dasar yang diderita adalah Rp 4.178.696.388,-. Faktor pengendali kerugian adalah 0,56, sehingga kerugian sebenarnya jika terjadi kebakaran danledakan adalah Rp 2.340.069.958,-. Lama hari kerja yang hilang jika terjadi kebakaran dan ledakan adalah 23 hari dan besarnya kerugian yang diderita apabila bisnis terhenti sementara adalah Rp 2.597.849.793,-.Kata Kunci:Premium, tangki timbun, kebakaran dan ledakan, analisis kerugian.
Read More
S-7612
Depok : FKM-UI, 2013
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Henry Krisyanto Parulian; Pembimbing: Fatma Lestari; Penguji: Yulianto S. Nugroho, Dadan Erwandi
S-5956
Depok : FKM-UI, 2010
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Sari Tua Roy Nababan; Pembimbing: Chandra Satrya; Penguji: Robiana Modjo, Delvi Yolanda
S-6402
Depok : FKM UI, 2011
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Ida Rosida; Pembimbing: Chandra Satrya; Penguji: Ridwan Z. Sjaaf, Ellen Happy Forever
S-6336
Depok : FKM UI, 2011
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Ika Hartin Atmaja; Pembimbing: Fatma Lestari; Penguji: Mila Tejamaya, Devie Fitri Octaviani
S-7618
Depok : FKM UI, 2013
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Lisna Utami; Pembimbing: Fatma Lestari; Penguji: Mila Tejamaya, Devie Fitri Octaviani
Abstrak:
Perusahaan minyak dan gas biasanya menggunakan tangki timbun yang berisi bahanmudah terbakar dan berbahaya bagi kesehatan, oleh karena itu risiko untuk terjadinya dispersigas, kebakaran, dan ledakan sangat besar apabila terjadi failure pada tangki timbun.Pemodelan yang dilakukan pada penelitian ini ditujukan untuk mengetahui konsekuensi dari peristiwa dispersi gas, kebakaran, dan ledakan akibat kebocoran pada tangki timbun premiumdengan kapasitas 5000 kiloliter di PT Pertamina (Persero) Terminal BBM Panjang, Lampung yang merupakan suatu perusahaan minyak dan gas. Penelitian ini merupakan penelitian pemodelan kuantitatif. Pemodelan dilakukan menggunakan piranti lunak BREEZE IncidentAnalyst pada tiga jenis hidrokarbon yang menjadi komponen Premium, yaitu heksana,heptana, dan pentana.Hasil dari penelitian ini didapatkan jangkauan dan konsekuensi dispersi gas, kebakaran,dan ledakan untuk tiga zona berdasarkan level of concern dari setiap skenario. Jangkauan dan konsekuensi dari pemodelan ini akan dianalisis terhadap sistem fire safety dan manajemen tanggap darurat yang ada di PT Pertamina (Persero) Terminal BBM Panjang, Lampung.
Kata kunci : BREEZE Incident Analyst, tangki timbun, Premium, konsekuensi, dispersi gas, kebakaran,kolam api, BLEVE, ledakan.
Oil and gas industries normally use storage tanks containing flammable materials and hazardous to health, therefore the risk for the occurrence of gas dispersion, fire, andexplosion is very high when the failure happened storage tank. Modeling performed in thisstudy aimed to determine the consequences of the events of gas dispersion, fire and explosiondue to leakage in the Premium storage tank with a capacity of 5000 liters at PT Pertamina(Persero) Terminal BBM Panjang, Lampung which is an oil and gas industry. This research isa quantitative modeling. Modeling done using software BREEZE Incident Analyst at threetypes of hydrocarbons that become Premium components, namely hexane, heptane, andpentane.Results of this research are presented range and consequences of gas dispersion, fire,and explosion for the three zones based on the level of concern of each scenario. The rangeand consequences of this modeling will be analyzed by the system fire safety and emergencymanagement in PT Pertamina (Persero) Terminal BBM Lampung, Lampung.
Keywords:BREEZE Incident Analyst, storage tank, Premium, consequences, gas dispersion, fire, poolfire, BLEVE, explosion
Read More
Kata kunci : BREEZE Incident Analyst, tangki timbun, Premium, konsekuensi, dispersi gas, kebakaran,kolam api, BLEVE, ledakan.
Oil and gas industries normally use storage tanks containing flammable materials and hazardous to health, therefore the risk for the occurrence of gas dispersion, fire, andexplosion is very high when the failure happened storage tank. Modeling performed in thisstudy aimed to determine the consequences of the events of gas dispersion, fire and explosiondue to leakage in the Premium storage tank with a capacity of 5000 liters at PT Pertamina(Persero) Terminal BBM Panjang, Lampung which is an oil and gas industry. This research isa quantitative modeling. Modeling done using software BREEZE Incident Analyst at threetypes of hydrocarbons that become Premium components, namely hexane, heptane, andpentane.Results of this research are presented range and consequences of gas dispersion, fire,and explosion for the three zones based on the level of concern of each scenario. The rangeand consequences of this modeling will be analyzed by the system fire safety and emergencymanagement in PT Pertamina (Persero) Terminal BBM Lampung, Lampung.
Keywords:BREEZE Incident Analyst, storage tank, Premium, consequences, gas dispersion, fire, poolfire, BLEVE, explosion
S-7620
Depok : FKM UI, 2013
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Kemas Ahmad Widad; Pembimbing: Fatma Lestari; Penguji: Zulkifli Djunaedi, Muhammad HIkam, Masjuli
Abstrak:
Tesis ini membahas mengenai analisis yang dilakukan terhadap faktor-faktor yang dapat menyebabkan terjadinya kebakaran pada saat penerimaan di tangki timbun BBM. Dilatar belakangi oleh kejadian kebakaran T.24 Depot Plumpang, penulis melakukan pengukuran persentase LBL (Lower Explosion Limit) di atas tangki timbun, pengukuran MIE (Minimum lgnition Energy), dan energi akibat gesekan peralatan yang digunakan. Dari hasil pengukuran persentase LEL didapat kondisi di atap tangki timbun BBM pada saat penerimaan BBM berlangsung merupakan kondisi yang flammable, baik pada waktu siang maupun malam hari dimana persentase LEL 30 % didapat pada jarak sekitar 3 meter dari sumber. Sedangkan dari pengukuran MIE didapatkan hasil BBM klas 1 yang didapat dari pengujian ini didapat antara 0,25 Joule sampai dengan 0.274 Joule dan dalam kondisi LEL 20% sampai dengan 40%. Dimana untuk Premium 0.274 Joule pada LEL 40 %. Pertamax 0,243 Joule pada LEL 30% dan Pertamax Plus 0.25 Joule pada LEL 20%. Pertamax plus mempunyai minimum ignition energy yang lebih kecil dibandingkan premium dan pertamax. Untuk energi gesekan didapatkan hasil energi minimal pada material tali cotton sebesar 7,4 E -9 J dan maksimal pada material dipstick stainless 4,5 I li-5 J. Hasil penelitian merekomendasikan untuk tidak diperbolehkan adanya kegiatan di atas tangki selama penerimaan BBM berlangsung.
This thesis will explain further about analysis of factors which can caused fire in receiving fuel storage tank activities. Tank fire in T. 24 Depot Plumpang, is what forms the background of this thesis. The writer will do some measurements such as persentage of LEL (Lower Explosion Limit), MIE (Minimum Ignition Energy) on the top of the fuel storage tank and also energy that occurs because of friction with equipments which are been used. From the measurement of LEL's percentage, the result is, the condition at the top of fuel storage tank when receiving activity is done will be in flammabe circumstances, either in the afternoon or in the night, where the percentage of LEI is 30% about 3 meter far from the source. From MIE measurement the result of class I fuel is 0.25 Joule-0,274 Joule in LEL's condition of` 20%-40%. For premium 0.274 Joule in LEL's percentage of 40 %. Pertamax 0.243 Joule in LEL`s percentage of` 30% dan Pertamina Plus 0.25 Joule in LEL's percentage of` 20%. Pertamax plus has the Smallest minimum ignition energy compared with premium and pertamax. For friction energy, the result is, minimum energy in cotton rope is 7,4 E -9 J and maximum energy in dipstick stainless material is 4,5l E-5 J. The researcher suggests that to not doing activity on the top of fuel storage tank when receiving activity is done.
Read More
This thesis will explain further about analysis of factors which can caused fire in receiving fuel storage tank activities. Tank fire in T. 24 Depot Plumpang, is what forms the background of this thesis. The writer will do some measurements such as persentage of LEL (Lower Explosion Limit), MIE (Minimum Ignition Energy) on the top of the fuel storage tank and also energy that occurs because of friction with equipments which are been used. From the measurement of LEL's percentage, the result is, the condition at the top of fuel storage tank when receiving activity is done will be in flammabe circumstances, either in the afternoon or in the night, where the percentage of LEI is 30% about 3 meter far from the source. From MIE measurement the result of class I fuel is 0.25 Joule-0,274 Joule in LEL's condition of` 20%-40%. For premium 0.274 Joule in LEL's percentage of 40 %. Pertamax 0.243 Joule in LEL`s percentage of` 30% dan Pertamina Plus 0.25 Joule in LEL's percentage of` 20%. Pertamax plus has the Smallest minimum ignition energy compared with premium and pertamax. For friction energy, the result is, minimum energy in cotton rope is 7,4 E -9 J and maximum energy in dipstick stainless material is 4,5l E-5 J. The researcher suggests that to not doing activity on the top of fuel storage tank when receiving activity is done.
T-3260
Depok : FKM-UI, 2010
S2 - Tesis Pusat Informasi Kesehatan Masyarakat
☉
Delia Anita; Pembimbing: Zulkifli Djunaidi
M-680
[s.l.] :
[s.n.] :
s.a.]