Ditemukan 8096 dokumen yang sesuai dengan query :: Simpan CSV
Bulletin Keslingmas, VIII, No.31, Juli - Sept. 1989, hal. 15-20, ( Cat. ada di bendel 1987 - 1996 )
[s.l.] :
[s.n.] :
s.a.]
Indeks Artikel Jurnal-Majalah Pusat Informasi Kesehatan Masyarakat
☉
Bulletin Keslingmas, VIII, N0.32, Okt. - Des. 1989, hal. 13-20, ( Cat. ada di bendel 1987- 1996 )
[s.l.] :
[s.n.] :
s.a.]
Indeks Artikel Jurnal-Majalah Pusat Informasi Kesehatan Masyarakat
☉
Bulletin Keslingmas, VIII, No.30, April - Juni 1989, hal. 35-37, ( Cat. ada di bendel 1987 - 1996 )
[s.l.] :
[s.n.] :
s.a.]
Indeks Artikel Jurnal-Majalah Pusat Informasi Kesehatan Masyarakat
☉
Di`amah Dewi Salma; Pembimbing: I Made Djaja; Penguji: Laila Fitria, Nurul Khotimah
Abstrak:
Berdasarkan evaluasi pengelolaan limbah medis Provinsi Banten (Hasil Wasdal Limbah Medis Tahun 2013) dari 50 Rumah Sakit/RSIA/Rumah Bersalin didapatkan 24 RS (49%) telah memiliki IPAL yang berfungsi dengan baik dan sebanyak 25 RS (51%) IPAL tidak berfungsi dengan baik. Penelitian ini dilakukan untuk melihat gambaran efektivitas Instalasi Pengolahan Air Limbah (IPAL) dalam Memperbaiki Kualitas Air Limbah (COD, BOD, TDS,TSS, Amoniak, Coliform, dan Minyak Lemak) Rum ah Sakit X, Y, dan Z di Cilegon tahun 2017. Penelitian ini dilakukan di Rumah Sakit X, Y, Z Kota Cilegon menggunakan data sekunder dari data arsip Rumah Sakit X, Y, Z dan Dinas Lingkungan Hidup Kota Cilegon secara deskriptif observasional. Data tersebut diolah dengan menghitung persentase efektivitas IPAL dan uji wilcoxon untuk melihat ada atau tidaknya perubahan sebelum dan sesudah pengolahannya.Berdasarkan uji wilcoxon, hasil penelitian menemukan bahwa IPAL Rumah Sakit X sudah efektif dalam memperbaiki kualitas air limbah, IPAL Rumah Sakit Y belum efektif dalam memperbaiki nilai TDS air limbah, dan IPAL Rumah Sakit Z belum efektif dalam memperbaiki nilai BOD air limbah. Simpulan dari penelitian ini adalah Rumah Sakit X, Y, Z memiliki nilai efektivitas yaitu berkisar 20-99%, IPAL Rumah Sakit X lebih efektif dalam memperbaiki kualitas air limbah.
Read More
S-9892
Depok : FKM UI, 2019
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Dewi Sulistyowati; Pembimbing: I Made Djaja; Penguji: Budi Hartono, Edeng Rachmat
Abstrak:
ABSTRAK Nama : Dewi Sulistyowati Program Studi : Kesehatan Lingkungan Judul : EfektifitasInstalasiPengolahan Air Limbah (IPAL) dalammemperbaikikualitas air limbah(COD, BOD, TSS, MinyakdanLemak, Amonia (NH3), dan Total Coli) di RumahSakitIbudanAnakRestiMulyaTahun 2017. Rumah Sakit Ibu dan Anak Resti Mulya dalam mengelola limbah cair menggunakan IPAL dengan sistem biofilter aerob-anaerob pada tahun 2014. Penelitian ini membahas efektifitas Instalasi Pengolahan Air Limbah di Rumah Sakit Ibu dan Anak Resti Mulya. Penelitian ini merupakan penelitian yang bersifat deskripsi observasional dengan pendekatan cross sectional. Hasil Penelitian terhadap kualitas effluent untuk parameter TSS, COD, BOD, minyak dan lemak tidak melebihi baku mutu yang ditetapkan oleh Pergub DKI Jakarta No. 69 tahun 2013 dan MenLH No. 05 tahun 2014. Sedangkan untuk parameter amonia dan total Coliform melebihi baku mutu yang ditetapkan. Rata-rata kualitas effluent untuk masing-masing parameter adalah : TSS 22,96 mg/L, amonia 8,90 mg/L, minyak dan lemak 0,995 mg/L, COD 50,61 mg/L, BOD 15,43 mg/L, dan total Coliform adalah sebesar 5.838 MPN/100 ml. Sedangkan berdasarkan analisis hasil laboratorium, efisiensi penurunan kadar pencemar untuk setiap parameter adalah : TSS 25,27%, amonia 56,26%, minyak dan lemak 50,37%, COD 54,36%, BOD 34,17%, dan total Coliform sebesar 60.81%. Persentase efisiensi IPAL dapat diketahui tidak hanya berdasarkan hasil outlet melainkan dengan menguji inlet secara berkala. Apabila parameter amonia, BOD, dan COD melebihi baku mutu yang telah ditetapkan , maka tindakan yang dapat dilakukan adalah dengan memperbaiki sistem aerasi dan melakukan treatment dengan menambahkan zat penetral seperti PAC.
Kata kunci : Efektifitas, IPAL, TSS, COD, BOD, Minyak dan Lemak, Amonia, Total Coliform
Mother and Child Resti Mulya Hospital in managing Waste Water Treatment Plant (WWTP) with aerob-anaerob biofilter system in 2014. This research discuss effectiveness of Waste Water Treatment Plant Installation at Resti Mulya Hospital. This research is an observational description with cross sectional approach. The result of the research on the effluent quality for TSS, COD, BOD, Oil and fat parameters do not exceed the quality standard specified by Jakarta governor regulation No. 69/2013 and regulation of environment minister number 05/2014. As for amonia and total Coliform parameters exceeded standard Quality set. The average quality of effluent for each parameter are TSS 22,96 mg/L, amonia 8,90 mg/L, oil and fat 0,995 mg/L, COD 50,61 mg/L, BOD 15,43 mg/L, and the total Coliform is 5,838 MPN/100 ml. While based on laboratory analysis, efficiency of decreasing pollutant level for each parameter are : TSS 25,27%, ammonia 56,26%, oil and fat 50,37%, COD 54,36%, BOD 34,17% and total colimorm amounted to 60,81%.The percentage of WWTP efficiency can be known not only based on outlet results but by regularly testing the inlet. If the ammonia, BOD, and COD parameters exceed the predefined quality standard, then the action that can be done is to improve the aeration system and perform treatment by adding a neutralizing agent such as PAC.
Keyword : Effectiveness, WWTP, TSS, COD, BOD, Oil and Fat, Amonia, Total Coliform
Read More
Kata kunci : Efektifitas, IPAL, TSS, COD, BOD, Minyak dan Lemak, Amonia, Total Coliform
Mother and Child Resti Mulya Hospital in managing Waste Water Treatment Plant (WWTP) with aerob-anaerob biofilter system in 2014. This research discuss effectiveness of Waste Water Treatment Plant Installation at Resti Mulya Hospital. This research is an observational description with cross sectional approach. The result of the research on the effluent quality for TSS, COD, BOD, Oil and fat parameters do not exceed the quality standard specified by Jakarta governor regulation No. 69/2013 and regulation of environment minister number 05/2014. As for amonia and total Coliform parameters exceeded standard Quality set. The average quality of effluent for each parameter are TSS 22,96 mg/L, amonia 8,90 mg/L, oil and fat 0,995 mg/L, COD 50,61 mg/L, BOD 15,43 mg/L, and the total Coliform is 5,838 MPN/100 ml. While based on laboratory analysis, efficiency of decreasing pollutant level for each parameter are : TSS 25,27%, ammonia 56,26%, oil and fat 50,37%, COD 54,36%, BOD 34,17% and total colimorm amounted to 60,81%.The percentage of WWTP efficiency can be known not only based on outlet results but by regularly testing the inlet. If the ammonia, BOD, and COD parameters exceed the predefined quality standard, then the action that can be done is to improve the aeration system and perform treatment by adding a neutralizing agent such as PAC.
Keyword : Effectiveness, WWTP, TSS, COD, BOD, Oil and Fat, Amonia, Total Coliform
S-9515
Depok : FKM UI, 2017
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
R. Herruly A.; Pembimbing: Sri Tjahjani Budi Utami
S-2683
Depok : FKM UI, 2002
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Ahmad Mauladi; Pembimbing: Sumengen Sutomo
S-4029
Depok : FKMUI, 2004
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Bulletin Keslingmas, VIII, No.30, April - Juni 1989, hal. 8-20, ( Cat. ada di bendel 1987 - 1996 )
[s.l.] :
[s.n.] :
s.a.]
Indeks Artikel Jurnal-Majalah Pusat Informasi Kesehatan Masyarakat
☉
Haniah Putri Soraya; Pembimbing: Ema Hermawati; Penguji: Budi Hartono, Muhammad Gama Prastowo
Abstrak:
Penelitian ini membahas tentang pengaruh variasi waktu tinggal limbah cair yang dihasilkan dari proses painting atau pegecatan terhadap penurunan kadar TSS dan COD pada instalasi pengolahan limbah cair di PT Astra Otoparts Tbk. Divisi Adiwira Plastik. Penelitian ini merupakan penelitian eksperimen. Metode analisis yang digunakan untuk mengetahui nilai COD dengan metode sprektrometri dan metode analisa TSS secara grafimetri. Hasil penelitian menunjukkan bahwa variasi waktu tinggal yang diberikan yaitu 1 jam, 2 jam, dan 4 jam, dapat menurunkan kadar TSS dan COD pada instalasi pengolahan limbah cair di PT Astra Otoparts Tbk. Divisi Adiwira Plastik. Efektifitas penurunan kadar TSS dan COD dengan presentase tertinggi pad waktu tinggal 4 jam sebesar 89,86% (TSS) dan sebesar 61,32% (COD). Kata kunci : Instalasi Pengolahan Limbah Cair (IPLC), Waktu Tinggal, Koagulasi, Flokulasi, Filtrasi This study discusses the influence of variation of liquid waste residence time resulting from the painting process or discharge to the decrease of TSS and COD levels in the waste water treatment plant at PT Astra Otoparts Tbk. Division of Plastic Adiwira. This research is an experimental research. The analytical method used to find out the value of COD by sprektrometri method and TSS analysis method by grafimetri. The results showed that the variation of residence time given is 1 hour, 2 hours, and 4 hours, can decrease the level of TSS and COD on the waste water treatment plant at PT Astra Otoparts Tbk. Division of Plastic Adiwira. The effectiveness of the decrease of TSS and COD content with the highest percentage of 4 hours residence time time was 89,86% (TSS) and 61,32% (COD). Keywords : Installation of Waste Water Processing (IPLC), Retention Time, Coagulation, Flocculation, Filtration
Read More
S-9611
Depok : FKM-UI, 2018
S1 - Skripsi Pusat Informasi Kesehatan Masyarakat
☉
Yustina Malur, Marylin S. Junias, Sintha L. Purimahua
JPGK Vol.2, No.1
Kupang : IAKMI - FKM Undana, 2010
Indeks Artikel Jurnal-Majalah Pusat Informasi Kesehatan Masyarakat
☉
