As a business and economic center, many office buildings in DKI Jakarta are bustling with activity. Fires in buildings can be caused by electrical equipment short circuits or human negligence. This study aims to analyze the implementation of emergency response systems in the event of a fire at the PT X headquarters based on NFPA 1660 Standard for Emergency, Continuity, and Crisis Management: Preparedness, Response and Recovery. This study employs a descriptive research design with a semi-quantitative approach. The data used include primary data such as interviews and observations, as well as secondary data in the form of company documents and literature reviews. The collected data were analyzed using a checklist form to assess the compliance of the existing emergency response system with NFPA 1660, 2024 edition. The research results indicate that the compliance of the emergency response system implementation in fire incidents at PT X, after being analyzed using NFPA 1660, shows that there are 4 variables with adequate compliance, 6 variables with partially adequate compliance, and 2 variables with inadequate compliance. The research results are expected to encourage PT X to consider the recommendations provided to further develop the emergency response system already in place at the company.
The growth of multi-storey buildings and offices have hazard potential to become disaster like fire that need to be consider an emergency response system to minimize the impact of losses in terms of material and human through step of mitigation, prevention, and early detection. This study aims to look at describtion of emergency response system (Emergency Response Preparedness) in pre, during, and post disaster of fire in the building of Balaikota Depok based on standard of NFPA 1600: Standard on Disaster / Emergency Management and Business Continuity Programs. This study uses descriptive analytic design with a qualitative approach. From this study, it can be concluded that the emergency response system for fire hazard in the building of Depok City Hall was not optimally and comprehensive. Keywords : Emergency Response System, Fire, NFPA 1600
HFACS (Human Factor Analysis and Classification System) is an approach that has been widely used in investigating accidents to find out weaknesses in an organization. This HFACS consists of four layers, namely unsafe act, precondition to unsafe act, unsafe supervision and organizational influence. Accidents can be prevented by closing holes at each defense layer. The HFACS principle is implemented to identify factors that contribute at unsafe driving behavior at PT. X, an oil company in Indonesia. Based on research finding, drivers who commit unsafe behavior are drivers with age 44 - 55 years (77.7%), experience over 16 years (63.1%), carried out on public roads (80.6%), on the afternoon shift (81, 6%), with a position as a team member (64.1%) and in the northern part of the company (56.3%). Weaknesses at the unsafe act level are decision errors (58.3%) ie not consistently applying risk assessment and not implementing safe work procedures. Weakness at level 2 is adverse mental state (52.4%), namely lack of focus in driving. Weakness at level 3 is inadequate supervision (65%) lack of consistent level of supervision to conduct safety supervision. Weakness at level 4 is the lack of consistency in the implementation of operational processes (62.1%), namely the implementation of risk assessment in an organization
Ship fires are still a significant contributor to accidents in Indonesia and abroad. Failure to respond to a fire emergency can cause great losses such as damage to property, pollution of the environment, damage to reputation and even loss of life. Continued efforts are needed to ensure the readiness of the crew, programs, facilities and infrastructure as well as management can respond to fire emergencies properly. This study aims to explain the preparedness of a fire emergency on a delay ship based on SOLAS CHAPTER II-2 regulations and supporting regulations such as ISM Code Chapter 8, SOLAS Chapter (III, IV and V) in the company PT. ABC in 2020. This research is a descriptive analytic study by analyzing secondary data at PT. ABC on the regulation of SOLAS and ISM Code, next is to provide recommendations from the results of the analysis. The results showed the percentage value for emergency response programs, especially programmed fire hazard identification is 50% level of compliance with the standard, for facilities and infrastructure are: 1. Compliance with LSA (Life Saving Appliances) in general from 6 categories already fulfilled, there are categories that fulfill 67%, 2. Compliance with Fire Protection and Fire Fighting Equipment from 11 categories in general has fulfilled there are several categories whose fulfillment is below 100%, Air-recharging system for SCBAs (0%), Self-contained breathing apparatuses (SCBAs) (80%), Fixed fire-detection and alarm systems (60%), Wheeled (mobile) fire extinguishers (71%) xi 3. Fulfillment of Fixed firefighting systems in general have met, of the 7 categories there are parts that are still below 100%, 4. Fulfillment of radio and navigational equipment there are parts below 100%. In general, the overall level of preparedness for tugboat emergency response at PT. ABC of SOLAS and ISM is in the range of 50-100%, the component that needs attention from management is the availability of tools to conduct inspections, testing and maintenance in accordance with the standards, so that compliance can be maintained and improved continuously.
One of the causes of loss of life in a fire incident in a building is a building that is not fast occupants evacuated. This study discusses the evaluation of the facility Emergency Response Preparedness (ERP) in the Gedung Pusat Admnistrasi (GPA) and the Maintenance Office building (MO) PT Pupuk Kujang, as well as provide an overview of the evacuation in the event of an emergency in the building. This type of research uses descriptive design based on observations and interviews. The purpose of this study was to determine the condition of the means of ERP in both the building and an idea of how the evacuation process to do if an emergency occurs. For means of ERP, as a means of escape, emergency exit, fire escape stairs, emergency lighting, evacuation directions and a assembly point not fully comply with specified standards of NFPA No. 101 and Permen PU. 26/PRT/M/2008. For emergency response procedures, ranging from planning to response has been well documented in the "Prosedur Emergency dan Evakuasi", but the procedure is an emergency response procedures for emergency response in the plant, not in the building. Later in the procedure, there are some elements that are not in accordance with the provisions of the ISRS, the number of personnel and equipment P3K are still not sufficient quantity. Based on these results, the authors suggested that the company establish procedures and emergency response teams in particular buildings, to improve the performance of the K3 performance and emergency response team to meet all the components supporting the evacuation of the building. Among other inspection activities to further improve the means of ERP, ERP redesigning facilities when possible, emergency training in the two buildings on a regular basis and increase the number of personnel P3K.