Hasil Pencarian :: Kembali

Ditemukan 33103 dokumen yang sesuai dengan query ::  Simpan CSV
cover
Garna Abdima; Pembimbing: Dadan Erwandi; Penguji: Fatma Lestari, Alfajri Ismail
S-6593
Depok : FKM UI, 2011
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Imran Zulkarnain Gultom; Pembimbing: Dadan Erwandi; Penguji: Fatma Lestari, Yuni Kusminanti
S-5742
Depok : FKM-UI, 2009
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Haerun; Pembimbing: Fatma Lestari; Penguji: Mila Tejamaya, Devie Fitri Octaviani
Abstrak: Merujuk pada ketentuan ILO (International Labour Organizations), perusahaanpetrokimia merupakan perusahaan yang dikategorikan sebagai perusahaan denganrisiko Major Hazard. PT Pupuk Kujang melibatkan amonia untuk prosesproduksinya yang disimpan pada tanki penyimpanan 10000 MT. Meskipun peristiwakebocoran pada tanki amonia di PT Pupuk Kujang belum pernah terjadi, akan tetapirisiko kebocoran tersebut seluruhya masih tetap ada. Penyimpanan amonia di PTPupuk Kujang masih menyimpan potensi-potensi terjadinya kerusakan atau gangguanpada proses penyimpanannya yang dapat merusak tanki, sehingga timbul kebocoranamonia dalam jumlah besar. Dengan kemungkinan tersebut PT Pupuk Kujang memerlukan analisis konsekuensi untuk dijadikan landasan perencanaan sistemtanggap darurat jika skenario kebocoran dalam jumlah besar terjadi.Dalam studi ini analisa konsekuensi kebocoran dilakukan dengan menggunakan BREEZE Incident Analyst. Hasil Penelitian menunjukan bahwa terjadinya bahayadan dampak kebocoran dapat disebabkan oleh kegagalan major dan kegagalan minoryang dianalisa dengan Fault Tree Analysis jarak dispersi terjauh mencapai lebih dari 262.6 m dengan kadar amonia 25 ppm dan 164.6 m untuk kadar 150 ppm dan116.9 m untuk kadar 750 ppm. Daerah yang berisiko terkena sebaran dispersiamonia dalam berbagai skenario adalah Pabrik Kujang 1A, utility Pabrik Kujang1B,cooling tower dan refrigerant amoniaKata kunci: Storage tank, Amonia, dispersi , BREEZE Incident analyst, Fault TreeAnalysis
According to ILO convention (International Labour Organizations), petrochemicalinstallation is one among other industry with a major hazard risk involved in theindustrial process. PT Pupuk Kujang Involved ammonia in the production processsaved on 10000 MT capacity storage tank. Although there is no leaking history forammonia storage tank at PT Pupuk Kujang it does not mean the potential for theevent to happen became impossible. The ammonia storage process still process thepotential of a mishap, malfunction or damage that could jeopardize the integrity ofthe storage tank an eventually leakage could occur. With this background, anconsequence analysis required for PT Pupuk Kujang around the facility to understandthe hazard and risk possibly occur, so proper mitigation and emergency plan could beproduce.In this study, the analysis of the consequences of leakage performed using BREEZEIncident Analyst . This studies show that the occurrence and impact of leakage can becaused by the failure of major and minor failures were analyzed by Fault TreeAnalysis, The projection produced by BREEZE Incident Analyst show the maximumdispersion distance is more 262.6 m with 25 ppm ammonia concentration and164.6 m for 150 ppm ammonia concentration and 116.9 m for 750 ppm ammoniaconcentration. Areas at risk of dispersion of the distribution of ammonia in variousscenarios are Factory Cleaver 1A, 1B Kujang utility plant, cooling tower andammonia refrigerant.Keywords : Storage tank, Ammonia, dispersion, BREEZE Incident analyst, FaultTree Analysis
Read More
S-7738
Depok : FKM-UI, 2013
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Fandita Tonyka Maharani; Pembimbing: Zulkifli Djunaidi; Penguji: Doni Hikmat Ramdhan, Adrianus Pangaribuan
Abstrak: Skripsi ini membahas analisis konsekuensi dispersi gas, kebakaran, danledakan di SPPBE PT Aroma Jaya Sejati Sragen. Skripsi ini merupakan penelitiansemi kuantitatif yang menggunakan data sekunder perusahaan dan observasi langsung kemudian dianalisis dengan menggunakan perangkat lunak ALOHA.Tujuan dari skripsi ini adalah untuk mengetahui jangkauan dan dampak dispersigas, kebakaran, dan ledakan di SPPBE PT Aroma Jaya Sejati Sragen akibat kebocoran tangki penyimpanan LPG yang dibagi menjadi propana dan butana.Hasil dari penelitian didapatkan threat zone dari pemodelan dispersi gas, jet fire, BLEVE (Boiling Liquid Expanding Vapour Explosion), dan Vapour Cloud Explosion dari propana dan butana. Selain itu dapat diketahui dampak radiasi panas dan tekanan ledakan serta didapatkan safe distance SPPBE PT Aroma Jaya Sejati.
Kata kunci : Analisis Konsekuensi, Threat Zone, SPPBE, Dispersi Gas, kebakaran, ledakan, Jet Fire, BLEVE, Vapour Cloud Explosion
This study is about consequence analysis of gas dispersion, fire, andexplosion of LPG storage tank in SPPBE PT Aroma Jaya Sejati Sragen. Thisstudy is semi quantitave study using secondary data and field observation then analyze them with ALOHA software. The purpose of this study is to find out theconsequences impact range of gas dispersion, fire and explosion due to leakage ofLPG storage tank which divided into propane and butane gas.The result of this study is threat zone from gas dispersion, jet fire, BLEVE,and Vapour Cloud Explosion modelling. The result can show the heat radiationand explosion pressure and safe distance of SPPBE PT Aroma Jaya Sejati Sragen.
Keywords : Consequence Analysis, Threat Zone, SPPBE, Gas Dispersion, fire,explosion, Jet Fire, BLEVE, Vapour Cloud Explosion
Read More
S-8061
Depok : FKM UI, 2014
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Putri Melati Dinanti; Pembimbing: Dadan Erwandi; Penguji: Fatma Lestari, Yuni Kusminanti
Abstrak: Skripsi ini membahas analisis konsekuensi dispersi gas, kebakaran, dan ledakanpada tangki timbun LPG di SPPBE PT Adikarya Pramita Perdana, Depok. Penelitian ini merupakan pemodelan kuantitatif dengan menggumpulkan data sekunder dan observasi lapangan yang dianalisis menggunakan perangkat lunak ALOHA (ArealLocation of Hazardous Atmosphere). Tujuan dari penelitian ini adalah untuk mengetahui jangkauan konsekuensi dari dampak dispersi gas, kebakaran, dan ledakanakibat kebocoran tangki timbun LPG yang dibagi menjadi gas propana dan butanaserta sistem fire safety dan manajemen tanggap darurat di SPPBE PT AdikaryaPramita Perdana.Hasil penelitian ini didapatkan konsekuensi dari pemodelan dispersi gasberacun akibat kebocoran tangki timbun LPG di SPPBE PT Adikarya PramitaPerdana, jangkauan penyebaran mencapai jarak 401 meter. Pada pemodelan jet firejangkauan mencapai jarak 159 meter, sedangkan BLEVE hingga 1 kilometer, serta pemodelan VCE mencapai jarak 330 meter. Lokasi atau area berbahaya akibatkebocoran ini terutama di SPPBE PT Adikarya Pramita Perdana dan juga populasiyang berisiko mencapai penduduk kelurahan Sukamaju, Jatijajar, dan Cilodong.Instalasi peralatan fire safety di SPPBE PT Adikarya Pramita Perdana sudah baik dan mengikuti standar PT Pertamina (Persero) serta sudah memiliki pedoman sistem manajemen tanggap darurat untuk penanganan beberapa keadaan darurat.Kata kunci: Analisis konsekuensi, LPG, Tangki timbun, SPPBE, ALOHA, Dispersigas beracun, Kebakaran, Jet Fire, BLEVE, Ledakan, Vapor cloud explosion, Fire safety, Manajemen tanggap darurat
This study is about consequence analysis of gas dispersion, fire, and explosionon LPG storage tank at SPPBE PT Adikarya Pramita Perdana, Depok. This study is aquantitative modeling with collecting secondary data and field observations thatanalyzed using ALOHA (Areal Location of Hazardous Atmosphere) software. Thepurpose of this study is to find out the consequences impact range of gas dispersion,fire and explosion due to leakage of LPG storage tank which divided into propaneand butane gas, also the description of fire safety system and emergency managementat SPPBE PT Adikarya Pramita Perdana.The results of this study is the range and consequences of modeling toxic gasdispersion due to leakage of LPG storage tank at SPPBE PT Adikarya PramitaPerdana, spreading range distance up to 401 meters. In jet fire model the range up to159 meters, while in BLEVE up to 1 kilometer, and VCE model up to 330 meters.The dangerous location or area due to this leakage at SPPBE PT Adikarya PramitaPerdana and the populations which is at risk reaches Sukamaju, Jatijajar, andCilodong. The installation of fire safety equipment at SPPBE PT Adikarya PramitaPerdana is already proper and meets the standard of PT Pertamina (Persero) and alsohas guidelines for emergency response management system for handling multiplecases of emergencies.Keywords: Consequence analysis, LPG, Storage Tank, SPPBE, ALOHA, Toxic gasdispersion, Fire, Jet fire, BLEVE, Explosion, Vapor cloud explosion, Firesafety, Emergency management
Read More
S-7684
Depok : FKM-UI, 2013
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Hesti Febyandini Lestari; Pembimbing: Laksita Ri Hastiti; Penguji: Fatma Lestari, Ambi Pradiptha
Abstrak: Toluene merupakan bahan kimia mudah terbakar dan beracun yang berfungsi sebagai solvent dalam produksi cat. Skripsi ini merupakan penelitian deskriptif dengan pendekatan semi kuantitatif menggunakan data sekunder perusahaan, literature serta observasi secara langsung yang kemudian di analisis menggunakan perangkat lunak Areal Location Hazardous Atmosphere (ALOHA). Tujuan dari penelitian ini adalah mengetahui konsekuensi yang terjadi berdasarkan jangakauan disperi uap toluene terhadap potensi keracunan, kebakaran, ledakan dan populasi berisiko terpajan dari skenario kebocoran tangki toluene yang sudah dirancang yakni dengan 4 jenis skenario cuaca pada kondisi overcast tinggi dan rendah serta kondisi cerah tinggi dan rendah. Hasil penelitian ini didapatkan dispersi uap beracun dan mudah dengan area jangkauan dispersi paling luas berasal dari skenario worst case (rupture crevice dan tidak terkendali) pada kondisi cuaca cerah dengan kecepatan angin dan suhu yang rendah pada gasket berukuran 4 inch yang dispersinya mencapai 438 meter yang mencakup seluruh wilayah Kawasan industri hingga pemukiman dan jalan raya publik, dan dispersi uap mudah terbakar dispersinya mencapai 69 meter yang mencakup hampir seluruh area PT. Inkote Indonesia. Sedangkan area konsekuensi radiasi termal paling luas berasal dari skenario worst case (rupture crevice dan tidak terkendali) pada kondisi cuaca mendung dengan kecepatan angin tinggi dan suhu yang rendah pada gasket berukuran 4 inch yang dispersinya mencapai 51 meter
Read More
S-10905
Depok : FKMUI, 2022
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Afri Dian Sari; Pembimbing: Fatma Lestari; Penguji: Zulkifli Djunaidi, Alfajri Ismail
S-7220
Depok : FKM-UI, 2012
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Efri Meikel; Pembimbing: Chandra Satrya; Penguji: Fatma Lestari, Yuni Kusminanti
S-7009
Depok : FKM-UI, 2012
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Dewi Mutia Rahayu; Pembimbing: Fatma Lestari; Penguji: Laksita Ri Hastiti, Nur Huda Salasa Majid
Abstrak:
Pertalite merupakan produk minyak yang diidentifikasi sebagai cairan yang dapat menyala lalu memicu kilatan api (flash fire) atau ledakan. PT X, sebuah perusahaan distribusi, menggunakan jalur maritim dan kapal tanker untuk mendistribusikan produk minyak ini. Salah satu jenis kapal tanker yang digunakan adalah Self Propelled Oil Barge (SPOB). Risiko tinggi bahaya kebakaran dan ledakan pada kapal tanker berasal dari produk minyak yang tergolong extremely flammable liquid. Penelitian ini merupakan penelitian deskriptif dengan pemodelan kuantitatif yang menggunakan data sekunder perusahaan, studi literatur, serta wawancara pekerja. Data tersebut kemudian dianalisis menggunakan perangkat lunak Areal Locations Of Hazadous Atmosphere (ALOHA) berdasarkan skenario terburuk. Tujuan dari penelitian ini adalah menganalisis konsekuensi kebakaran dan ledakan dari kebocoran tangki berupa jangkauan radiasi termal dari skenario kebakaran pool fire dan overpressure threat zone atau blast area dari skenario ledakan vapor cloud explosion. Hasil penelitian ini menunjukkan bahwa jangkauan konsekuensi kebakaran pool fire mencapai 95 meter, sementara ledakan vapor cloud explosion mencapai 558 meter. Oleh karena itu, penting bagi perusahaan untuk memperhitungkan konsekuensi kebakaran dan ledakan ini, mempertahankan sistem keselamatan kebakaran dan tanggap darurat yang sudah ada, serta melakukan sosialisasi mengenai konsekuensi kebakaran dan ledakan kepada pekerja, masyarakat, serta pihak dermaga.

Pertalite is an oil product identified as a flammable liquid that can ignite and cause flash fires or explosions. PT X, a company involved in oil distribution, employs maritime routes and tankers to transport this oil product. One of the tanker types used is the Self Propelled Oil Barge (SPOB). The high risk of fire and explosion hazards on tankers arises from the presence of extremely flammable liquids onboard. This research is a descriptive study that utilizes quantitative modeling, including company secondary data, literature reviews, and employee interviews. The data are then analyzed using the Areal Locations Of Hazardous Atmosphere (ALOHA) software based on worst-case scenarios. The aim of this study is to analyze the consequences of fire and explosion resulting from tank leaks, focusing on the thermal radiation coverage from pool fire scenarios and the overpressure threat zones or blast areas from vapor cloud explosion scenarios. The results of this study indicate that the range of consequences for pool fires reaches up to 95 meters, while vapor cloud explosions can extend up to 558 meters. Therefore, it is crucial for the company to consider the consequences of fire and explosion, maintain the existing fire safety and emergency response systems, and raise awareness among employees, the local community, and the dockyard about the potential risks of fire and explosion.
Read More
S-11286
Depok : FKM-UI, 2023
S1 - Skripsi   Pusat Informasi Kesehatan Masyarakat
cover
Ambi Pradiptha; Pembimbing: Fatma Lestari, Dadan Erwandi; Penguji: Mila Tejamaya, I Gusti Suarnaya Sidemen, Teguh Cahyono
Abstrak: Gas klorin merupakan bahan kimia yang berbahaya karena sifatnya yang beracun dankorosif. Klorin juga termasuk ke dalam Extremely Hazardous Substances (EHS) ataubahan yang berbahaya sekali karena gas klorin dapat menimbulkan kematian (EPA,1990). Penelitian ini membahas tentang analisis risiko kebocoran gas pada fasilitastangki penyimpanan klorin di PT XYZ dengan mengasumsikan adanya korosi padavalve dan fusible plug tangki klorin. Dianalisa menggunakan pendekatan ComputationalFluid Dynamics 3 dimensi yang diproses dengan meggunakan perangkat lunak FLACS.Desain penelitian menggunakan analisis risiko secara kualitatif dengan desain deskriptifdan menggunakan FTA untuk menentukan skenario kebocoran dengan menggunakandata sekunder. Dari hasil penelitian diketahui bahwa sebaran kebocoran gas klorin yangdihasilkan dari pemodelan berpotensi menyebar tidak hanya didalam area PT XYZnamun juga sampai ke pemukiman penduduk dengan tingkat konsentrasi yangbervariasi mulai dari angka tertinggi 300 ppmv sampai 10 ppmv. PT XYZ disarankanuntuk selalu melakukan pengecekan berkala pada fasilitas tangki klorin, melakukanpelatihan tanggap darurat kebocoran klorin dan audit berkala sebagai bentuk upayapencegahan kebocoran klorin.Kata kunci: Kebocoran klorin, FLACS, Sebaran gas klorin, FTA.
Read More
T-5227
Depok : FKM-UI, 2018
S2 - Tesis   Pusat Informasi Kesehatan Masyarakat
:: Pengguna : Pusat Informasi Kesehatan Masyarakat
Library Automation and Digital Archive