Ditemukan 34501 dokumen yang sesuai dengan query :: Simpan CSV
This thesis discusses the assessment of emergency response system in case of firein Grand Galaxy Park Mall. This study is a qualitative study that uses two types ofdata collection techniques, which are primary data in the form of interviews andobservations and secondary data from the study documents. The purpose of thisstudy is to assess the emergency response system in the Grand Galaxy Park Mall2016 with reference to the NFPA 1600 2013 Edition: Standard onDisaster/Emergency Management and Business Continuity Programs. The resultsof this study are expected in order to mall management can conduct a review ofthe advice given to improve their emergency response system and to see theappropriateness of using NFPA NFPA 1600 2013 Edition: Standard onDisaster/Emergency Management and Business Continuity Programs in assessingthe emergency response system of shopping center.Keywords: Emergency Response Systems, NFPA 1600 2013 Edition,Emergency/Disaster, Fire Hazard.
Ship fires are still a significant contributor to accidents in Indonesia and abroad. Failure to respond to a fire emergency can cause great losses such as damage to property, pollution of the environment, damage to reputation and even loss of life. Continued efforts are needed to ensure the readiness of the crew, programs, facilities and infrastructure as well as management can respond to fire emergencies properly. This study aims to explain the preparedness of a fire emergency on a delay ship based on SOLAS CHAPTER II-2 regulations and supporting regulations such as ISM Code Chapter 8, SOLAS Chapter (III, IV and V) in the company PT. ABC in 2020. This research is a descriptive analytic study by analyzing secondary data at PT. ABC on the regulation of SOLAS and ISM Code, next is to provide recommendations from the results of the analysis. The results showed the percentage value for emergency response programs, especially programmed fire hazard identification is 50% level of compliance with the standard, for facilities and infrastructure are: 1. Compliance with LSA (Life Saving Appliances) in general from 6 categories already fulfilled, there are categories that fulfill 67%, 2. Compliance with Fire Protection and Fire Fighting Equipment from 11 categories in general has fulfilled there are several categories whose fulfillment is below 100%, Air-recharging system for SCBAs (0%), Self-contained breathing apparatuses (SCBAs) (80%), Fixed fire-detection and alarm systems (60%), Wheeled (mobile) fire extinguishers (71%) xi 3. Fulfillment of Fixed firefighting systems in general have met, of the 7 categories there are parts that are still below 100%, 4. Fulfillment of radio and navigational equipment there are parts below 100%. In general, the overall level of preparedness for tugboat emergency response at PT. ABC of SOLAS and ISM is in the range of 50-100%, the component that needs attention from management is the availability of tools to conduct inspections, testing and maintenance in accordance with the standards, so that compliance can be maintained and improved continuously.
Kata kunci:Sistem proteksi aktif, proteksi pasif, sistem tanggap darurat, NFPA, KeputusanMenteri Pekerjaan Umum
This research is about the application of active and passive protection system andemergency response system of fire at PT Prasadha Pamunah Limbah Industri(PPLi). The purpose of this research is to understand about the compatibility ofthose system compare with Keputusan Menteri Pekerjaan Umum and NationalFire Protection Association, active and passive protection system and emeregencyresponse system of fire. This research use descriptive method through observationand document review. The conclusion of this research is the active and passiveprotection system and emergency response of fire at PT Prasadha PamunahLimbah Industri (PPLi) has not fully complied the standard.
Key words:Active protection system, passive protection system, emergency response system,NFPA, Keputusan Menteri Pekerjaan Umum